This 1200w Solar Inverter is low frequency inverter with built-in transformer, it is a hybrid solar inverter, can work with solar and AC grid, suitable for off grid home system. It is a pure sine wave inverter with AVR output, suitable for various loads. It has complete protection function, input over/low voltage, overload, short circuit, low battery voltage, over temperature etc.
1200w Solar Inverter
12vdc to 220ac 1200w solar inverter
1.Product Introduction
This series is low frequency inverter with built-in transformer, it is a hybrid solar inverter, can work with solar and AC grid, suitable for off grid home system. It is a pure sine wave inverter with AVR output, suitable for various loads. It has complete protection function, input over/low voltage, overload, short circuit, low battery voltage, over temperature etc.
2.Product Parameter (Specification)
Model |
GR series |
||||||
Rate power |
500W |
650W |
800W |
1000W |
1200W |
1500W |
|
Instant power |
Three times |
||||||
DC Input |
DC voltage |
12V |
12V |
12V |
12V |
24V |
24V |
|
12V Battery No. |
1pcs |
1pcs |
1pcs |
1pcs |
2pcs |
2pcs |
|
Battery type |
Maintenance-free lead-acid batteries |
|||||
AC Input |
Phase |
Single Phase |
|||||
|
Frequency |
50Hz ± 10% |
|||||
|
AC input |
110V(75-140V)/220V(145-275V) (L+N+G) |
|||||
|
AC AVR output |
110/220VAC (L+N+G)±10% |
|||||
ACCharger (option) |
Floating charge voltage |
14.5V |
14.5V |
14.5V |
14.5V |
29V |
29V |
|
Overcharge protect voltage |
15.5V |
15.5V |
15.5V |
15.5V |
31V |
31V |
|
Charge current |
10-20A adjustable (Charging current can be customized) |
|||||
SolarController (option) |
rated voltage |
DC12V |
DC12V |
DC12V |
DC12V |
DC24V |
DC24V |
|
maximum input voltage |
50V |
50V |
50V |
50V |
100V |
100V |
|
Max. charge current |
30A |
30A |
30A |
30A |
60A |
60A |
|
defective function |
Overcharging, overloading, overloading, low-voltage, short-circuit |
|||||
Invert output |
Output voltage |
110V/220VAC (L+N+G)±1% |
|||||
|
Frequency |
50Hz ± 0.1% |
|||||
|
THD |
≤ 3% (Linear load) |
|||||
|
Dynamic response |
5% (0%~100% load) |
|||||
|
Crest factor |
3:1 |
|||||
|
Invert efficiency |
97% |
|||||
Display |
LCD display panel |
||||||
Alarm |
Buzzing and LCD screen flicker |
||||||
Protection function |
Ac overvoltage, under voltage, DC overvoltage, under voltage, Overload, Output short circuit |
||||||
Overload capacity |
120%30s; 125% 10s;150% 0s |
||||||
Communication interface |
USB/RS232/SNMP/Wifi(option) |
||||||
Protection class |
IP21 |
||||||
Surge handling capability |
10/700US,5KVA;8/20US,20KA |
||||||
Noise dB |
≤45db |
||||||
Cooling mode |
Forced ventilation |
||||||
Ambient Temperature |
Temperature 0-40℃, relative humidity10%-90%, elevation<1000m |
||||||
Net Weight (kg) |
8 |
8.5 |
9 |
10 |
11 |
11.5 |
|
Size(mm) |
300*150*230 |