This 8kw Inverter is an off grid solar inverter, it is suitable for off grid home system. It is pure low frequency inverter, suitable for various loads. It is with internal mppt solar charger, can connect solar panel directly. It has complete protection function, input over/low voltage, overload, short circuit, low battery voltage, over temperature etc.
8kw Inverter/low frequency hybrid 8kw Inverter
Low frequency hybrid mppt solar inverter 8kw
1.Product Introduction
This 8kw solar inverter is an off grid solar inverter, it is suitable for off grid home system. It is pure low frequency inverter, suitable for various loads. It is with internal mppt solar charger, can connect solar panel directly. It has complete protection function, input over/low voltage, overload, short circuit, low battery voltage, over temperature etc.
2.Product Parameter (Specification)
Model |
GTYT8K |
GTYT10K |
GTYT12K |
GTYT15K |
||||
Rate Power |
8KW |
10KW |
12KW |
15KW |
||||
Instant power |
3 times |
|||||||
DC Input |
Batt. Voltage |
96V |
||||||
|
Batt. Number |
12V:8pcs |
||||||
|
Battery type |
All kinds of battery |
||||||
AC Input (optional) |
Phase |
Single |
||||||
|
Frequency |
50/60Hz ± 10% |
||||||
|
Input voltage |
220VAC (175-255V) (L+N+G) |
||||||
|
Output voltge |
220VAC directly |
||||||
Invert output |
Output voltage |
220VAC (L+N+G) ± 1% |
||||||
|
Frequency |
50/60Hz ± 0.1% |
||||||
|
Switch time |
T≤4ms |
||||||
|
THD |
≤ 3%(Linear load) |
||||||
|
Dynamic response |
5%(0%~100% load) |
||||||
|
Crest factor(CF) |
3:1 |
||||||
|
Invert efficiency |
97% |
||||||
MPPT controller |
Rated voltage |
96VDC |
||||||
|
Charge current |
100A |
||||||
|
Max power |
10KW |
||||||
|
Max input voltage |
230VDC |
||||||
|
MPPT range |
140-200VDC |
||||||
|
Recommend pv mppt voltage |
170V±10V |
||||||
|
Protection |
Over charge, over discharge, overload, low voltage, short circuit, reverse connection |
||||||
Display |
LCD Touch Screen+ LED |
|||||||
Alarm |
Buzzing and LCD screen flicker |
|||||||
Protection function |
Ac overvoltage, under voltage, DC overvoltage, under voltage, Overload, Output short circuit |
|||||||
Overload capacity |
120% 30s, 125% 10s, 150% 0s |
|||||||
Communication interface |
RS232/SNMP/Wifi (extra optional function) |
|||||||
Protection class |
IP21 |
|||||||
Surge handling capability |
10/700US,5KVA;8/20US,20KA |
|||||||
Noise dB |
≤45db |
|||||||
Cooling mode |
Forced ventilation |
|||||||
Ambient Temperature |
Temperature 0-45℃, relative humidity10%-90%, elevation<1000m |
|||||||
Size(L*W*H) |
400*580*720 |
|||||||
Weight(kg) |
79 |
87.5 |
94 |
118 |
1.LCDtouch screen |
4. AC DCPV breaker |
2.PV LED indicates |
5.Connection terminals |
3.ON/OFF button |
|